CONVENTIONAL RADIOGRAPHIC UNIT (STABLE)

  • Kilovoltage (kVp)
  • Exposure Time
  • Reproducibility
  • Radiation Output and Beam Quality
  • Filtration
  • X Ray Field Alignment
  • Focal Spot
  • Spatial Resolution
  • Grid Alignment
  • Leakage Radiation

Konvansiyonel Radyografi

CONVENTIONAL RADIOGRAPHIC UNIT (MOBILE)

  • Kilovoltage (kVp)
  • Reproducibility
  • Radiation Output and Beam Quality
  • Filtration
  • X Ray Field Alignment
  • Focal Spot
  • Spatial Resolution
  • Leakage Radiation

Konvansiyonel Radyografi (Mobil)

FILM PROCESSOR

  • Base + Fog Level and Darkroom Inspection
  • Speed Index
  • Contrast Index
  • Developer Inspection

Film Banyo

DENTAL RADIOGRAPHY (PERIAPICAL)

  • Kilovoltage (kVp)
  • Exposure Time
  • Radiation Output and Beam Quality
  • Filtration
  • X Ray Field Alignment
  • Focus-Patient Distance

Denral Radyografi

DENTAL RADIOGRAPHY (PANAROMIC)

  • Kilovoltage (kVp)
  • Exposure Time
  • Beam Quality
  • Filtration

Panoramik Dental

MAMMOGRAPHY

  • Physical Inspection
  • Reproducibility
  • Radiation Output and Beam Quality
  • Filtration
  • kVp Accuracy and Reproducibility
  • Automatic Exposure Control
  • X Ray Field Alignment
  • Average Glandular Dose
  • Homogeneity and Artefacts
  • Image Quality
  • Breast Compression
  • Breast Thickness
  • High Contrast Spatial Resolution
  • Leakage Radiation

Mamografi

DIGITAL AND CONVENTIONAL FLUOROSCOPY

  • Kilovoltage (kVp)
  • Radiation Output and Beam Quality
  • Automatic Brightness Control
  • Patient Entrance Skin Exposure
  • Maximum Fluoroscopic Entrance Skin Exposure
  • Input Radiation into the Image Intensifier
  • Filtration
  • Collimation
  • Grey Scale
  • Low Contrast Spatial Resolution
  • High Contrast Spatial Resolution

Print

COMPUTED TOMOGRAPHY (CT)

  • Internal Scan Localization Light Accuracy
  • Coronal and Sagittal Light Accuracy
  • Axial Motion
  • Helical Motion
  • Table Travel Indicator Accuracy
  • Table/Ganty Tilt
  • Exposed Slice Thickness
  • Imaged Slice Width
  • Kilovoltage (kVp)
  • Filtration
  • CTDI in Air
  • CTDI in Head and Body Phantom
  • CT Number Accuracy
  • CT Number Linearity
  • High Contrast Spatial Resolution
  • Low Contrast Spatial Resolution
  • İmage Noise

CT

DIGITAL RADIOGRAPHIC UNIT

  • Kilovoltage (kVp)
  • Exposure Time
  • Reproducibility
  • Radiation Output and Beam Quality
  • Filtration
  • X Ray Field Alignment
  • Focal Spot
  • Spatial Resolution
  • Grid Alignment
  • Leakage Radiation
  • Dark Noise
  • Linearity and System Transfer Properties
  • Image Retention
  • Detector Dose Indicator Consistency
  • Uniformity
  • Scaling Errors
  • Blurring and Stitching Artefacts
  • Limiting Spatial Resolution
  • Threshold Contrast Detail Detectability

DR

COMPUTED RADIOGRAPHIC UNIT

  • Kilovoltage (kVp)
  • Exposure Time
  • Reproducibility
  • Radiation Output and Beam Quality
  • Filtration
  • X Ray Field Alignment
  • Focal Spot
  • Spatial Resolution
  • Grid Alignment
  • Leakage Radiation
  • Monitor and Laser Printer Inspection
  • Dark Noise
  • Image Retention
  • Detector Dose Indicator Calibration
  • Detector Dose Indicator Consistency
  • Uniformity
  • Scaling Errors
  • Blurring
  • Limiting Spatial Resolution
  • Threshold Contrast Detail Detectability
  • Laser Function
  • Moire Artefacts

CR

VİEWING BOX

  • Viewing Box Brightness
  • Background Roomlight

Goruntuleme Panosu

ULTRASOUND AND ECHOCARDIOGRAPHY

  • Depth of Penetration
  • Vertical and Horizontal Distance Accuracy
  • Lateral Resolution
  • Axial Resolution
  • Uniformity
  • Dead Zone
  • Cystic Image (Shape, Tissue and Edges)

Ultrason

MAGNETIC RESONANCE IMAGING (MRI)

  • Geometric Accuracy
  • High Contrast Spatial Resolution
  • Slice Thickness Accuracy
  • Slice Position Accuracy
  • Image Intensity Uniformity
  • Percent Signal Ghosting
  • Low Contrast Object Detectability
  • Signal to Noise Ratio
  • Image Artefacts

MR